Machine cannot be switched on
Cause Troubleshooting
The main switch is not switched on Switch main switch to position "I"
Mains failure or Failureof a phase Wait for power to return or Remedy cause of power failure (e.g. defective operational side fuses)
Overload protection has triggered Pull sliding table back in front of saw blade
Sliding table moved beyond middle of saw blade Release the EMERGENCY STOP button again by pulling it
EMERGENCY STOPbutton pressed Close door or lower protective cover Switch off the main switch, open switching cabinet and determine which of fuses F1, F2, F8 is defective.
Door on machine standor lower protectivecover in front of thesaw blades opened Clarify and remedy cause
Control circuit fuses defective Replace defective fuses, use fuses of the same ratings as replacements!

Altendorf Qinhuangdao Machinery Manufacturing Co. Ltd.      Imprint            www.altendorf.com    

                                                     